Energy & grid

From plant to customer. Every point monitored.

Hover a part of the network to see what Waltero measures there, click it for details and use cases. Every pin is a W-Sensor reading the meters, gauges, panels and tanks you already have.

  • Power
  • Heat
  • Cooling
  • W-Sensor point

Renewable generation

Small hydro, solar parks and wind sites

Generation

The sites with no SCADA, read on schedule.

Small hydro plants, solar parks and older wind sites are visited on a round because they have no SCADA, or because the portal belongs to the turbine or inverter supplier. Waltero reads the generation meter, the gauges and the levels at each site at a set interval, so the owner has an up-to-date production figure and a log of the site's condition without the drive.

What we monitor

  • Generation meterDaily and hourly kWh from the existing generation meter, read in place, independent of the supplier's portal.
  • Intake, forebay and trash-rack levelVision AI reads the water level against a calibrated scale on both sides of the trash rack; a growing difference means it is time to clean it.
  • Hydraulic and lubrication gaugesPressure and oil-level gauges on the turbine's hydraulic and lubrication units, read at a set interval with alarms on drift.
  • Turbine and generator behaviourRun events, run duration and trends from a vibration fingerprint on bearings and gearboxes, with an alert on deviation from the normal pattern.
  • Inverter and controller displaysThe figures shown on the inverter or plant controller display, read on every check.

Learn more

Transmission substation

HV transformers, breakers and station auxiliaries

Electricity grid

Transformer gauges read every hour, not every quarter.

The main transformers and breakers already have gauges: oil level, winding and oil temperature, tap-changer counters, SF6 density on the breakers. Most are read by a technician on a scheduled visit and typed into a form. Waltero reads them in place at a set interval, outside the protection and control system, so condition is a trend rather than a quarterly snapshot.

What we monitor

  • Transformer oil level and temperatureVision AI reads the oil-level sight glass and the winding and oil temperature gauges; alarm on a rising trend or a falling level.
  • SF6 density gaugesThe density gauge on every breaker read at a set interval, so a slow leak is flagged long before the low-pressure lockout.
  • Tap-changer counterOperation counts from the existing counter, for maintenance planned on use rather than on the calendar.
  • Station auxiliariesBattery charger, panel meters and auxiliary supply figures from the existing displays, read on every check.
  • Indicator lamps and flagsA camera on the panel front flags a changed indicator or a dropped relay flag on the next check.

Learn more

Distribution substations

Secondary substations and the low-voltage grid

Electricity grid

Thousands of substations, one sensor each.

A distribution grid has hundreds or thousands of secondary substations and almost none of them report anything. Fitting an RTU to each is a project; fitting a W-Sensor is a visit. It reads the panel meters, the transformer gauges and the substation meter at a set interval, so load, condition and losses per substation are known without a rollout across the whole grid.

What we monitor

  • Load per substationCurrent, voltage and power from the panel meters in the LV board, read in place, for capacity planning and connection decisions.
  • Transformer temperature and oil levelThe gauges on the distribution transformer read at a set interval, with alarms before a summer peak becomes a failure.
  • Substation energy meterEnergy in against energy billed downstream, for loss calculation per substation.
  • Indicator lamps and trip flagsA tripped breaker or a changed indicator flagged on the next check.
  • Outage and anomaly alertsA reading that goes to zero, or a load that is not where it was yesterday, becomes an alarm in Mimir.

Learn more

Customer & grid meters

Electricity meters at customers, feeders and boundaries

Electricity grid

Smart-meter data from the meters you already have, with the power on.

A smart-meter rollout means a new meter, an electrician and a power cut at every customer, and years before the last one is done. A W-Sensor goes over the existing electricity meter in minutes, with the power on, and reads the register at a set interval. It has no electrical or data connection to the meter or the grid: it reads the display from the outside, so there is nothing to cut in and nothing to attack.

What we monitor

  • No power cut to installThe sensor mounts over the existing meter with a hinged adapter; the meter is never touched, the supply is never interrupted and no electrician is needed.
  • Air-gapped by designNo electrical or data connection to the meter, the customer's installation or the grid. Readings go out over the cellular network, encrypted and outbound only; nothing can be reached through the sensor, and interference with it is reported as tamper.
  • Consumption at the interval you chooseRegister readings from mechanical and digital meters at customers, feeders and grid boundaries, from every 15 minutes to once a day, for billing, load profiles and losses.
  • Anomalies and outagesA register that stops moving, a night baseline that changes or a load that vanishes becomes an alarm rather than a customer call.
  • Exact billing, no estimatesSame-day readings across a whole customer group end estimated bills and the disputes that follow.

Learn more

Power & heat plant

CHP, heat-only boilers and peak plants

Generation

The plant round, logged without the walk.

A CHP or heat plant is full of instruments that are checked on a round: fuel tank levels, boiler and steam gauges, feedwater and dosing, a meter in a corner nobody trusts. The peak boiler plant at the edge of town sees a technician once a week. Waltero reads the same instruments at a set interval, so the plant log keeps itself and a drifting reading becomes an alarm rather than a note in the shift book.

What we monitor

  • Fuel and additive tank levelsVision AI reads the level gauges on oil, bio-oil and additive tanks; reorder alarms at the level you set, and a falling level with no load flags a leak.
  • Boiler, steam and feedwater gaugesPressure gauges on boilers, steam headers and feedwater lines read in place, with alarms when a reading leaves its normal band.
  • Temperature displaysFlue-gas, supply and return temperatures read from the existing thermometers and panel displays at a set interval.
  • Water treatment dosingDrum levels for oxygen scavenger, pH and inhibitor dosing, so the treatment log is always current.
  • Feed and circulation pumpsRun events, duration and trends from a vibration fingerprint on feedwater and network pumps, with an alert on deviation from the normal pattern.
  • Plant metersMake-up water, gas and the plant's own electricity from the existing meters, at the same interval as everything else.

Learn more

Heat transmission & network

Transmission lines, valve chambers and network pits

District heating & cooling

Pressure and temperature at every chamber, without driving there.

A district heating network is judged at points nobody sees: pressure at the far end, differential pressure at the critical points, temperatures in valve chambers, water in the pits. Waltero reads the existing gauges and thermometers in the chambers at a set interval and sends the readings to Mimir, so the network's condition is a trend across the map rather than a set of visits.

What we monitor

  • Pressure at critical pointsSupply and return pressure gauges at the ends of the network and at the critical points, read in place, with alarms on drift.
  • Supply and return temperatureThermometers in the chambers read at a set interval, so the temperature profile along the line is known.
  • Water in valve pitsVision AI reads the water level in chambers and pits against a calibrated scale, flagging groundwater ingress or a leak before the pit is full.
  • Network flow and heat metersThe reading shown on flow and heat meters out in the network, read on every check.
  • Records for the network modelTimestamped readings that calibrate the hydraulic model and support the annual loss report.

Learn more

The city network

Every customer substation, meter and gauge on one screen

The city network

From manual rounds to continuous monitoring.

An energy company runs thousands of points nobody sees daily: customer heat substations in basements, secondary substations on street corners, gauges in valve chambers, tanks at the plant. Waltero puts a battery-powered W-Sensor on each of those points; it reads the existing meter, gauge or display at the interval you choose and sends every reading to Mimir, so the whole network is visible from one screen, and from the SCADA you already run. Anything a technician still drives to and writes down, a W-Sensor can read.

What we monitor

  • One view of the whole networkPlants, substations, chambers and customer sites in one view, with alarms to the on-call technician's phone.
  • Customer substations and metersHeat meters, return temperatures and electricity meters read in place at the customer, with no meter swap and no visit.
  • Feeds SCADA, billing and the work-order systemOpen API and MQTT into SCADA, the billing run and the maintenance system, so a reading out of band becomes a job.
  • Installed by your own crews or a partnerNo cabling, no outage: a sensor is fitted in minutes on the equipment already in place, from one plant to a whole network.

Learn more

Talk to us about your network

Heat storage & exchange stations

Accumulator tanks and pressure-step stations

District heating & cooling

Know what is in the tank and what the station is doing.

Accumulator tanks and heat exchange stations sit between the plant and the customers, usually unmanned. The tank's level and temperatures, the station's primary and secondary pressures and the pumps' behaviour are checked on a visit. Waltero reads them at a set interval, so charging and discharging the tank and running the station are decisions made on data.

What we monitor

  • Accumulator level and pressureLevel and pressure gauges on the tank read in place, with alarms on both limits.
  • Tank and station temperaturesTemperature displays and thermometers at the tank's layers and on both sides of the exchange station, read at a set interval.
  • Primary and secondary pressurePressure gauges on each side of the exchangers, so fouling and a control fault show up as a drift.
  • Station pumpsRun events, duration and trends from a vibration fingerprint on the circulation pumps, with an alert on deviation from the normal pattern.

Learn more

District cooling

Chillers, cooling towers and cold storage

District heating & cooling

The biggest summer load, measured properly.

District cooling plants run hardest when nobody wants to be in them. Chiller gauges, tower dosing, cold-storage tank levels and the plant's electricity are checked on a round. Waltero reads the same instruments at a set interval, so kWh per unit of cooling is known and a fan or compressor that starts behaving differently is a planned job.

What we monitor

  • Chiller and plant electricitykWh per chiller and for the plant from the existing meters, at the interval you set.
  • Chiller and chilled-water gaugesRefrigerant and chilled-water pressure gauges read in place.
  • Cold storage tank levelLevel in chilled-water storage tanks read against the sight glass or a calibrated scale.
  • Cooling tower dosingBiocide and inhibitor drum levels plus make-up water, so the Legionella treatment log is always current.
  • Compressor and fan behaviourRun events, duration and trends from a vibration fingerprint on compressors and tower fans, with an alert on deviation from the normal pattern.

Learn more

Tap an asset for details.

Mount. Read. See.

A W-Sensor mounts on the meter, gauge or display you already have, reads it at the interval you set, and sends the number to Mimir. Nothing on the asset changes, and nothing needs wiring.

W-Sensor
Hinged adapter, existing meterBattery powered
Last reading3.6 bartaken 14 min ago
Interval15 min1 h6 h24 h
Sprinkler riserBelow 4.0 bar
3.6 bar
Trend 30 dExcel · APIFeeds BMS
  1. Mount

    Fix a W-Sensor over the meter, gauge or display you already have. The adapter is hinged, so the meter stays readable and nothing on the asset is changed.

    No plumbing. No wiring. No downtime.
  2. Read

    At the interval you set, the sensor photographs the dial or display and reads the value on the device itself. Only the reading is transmitted, never a video stream; the image behind it is kept for audit.

    Hourly by default; from every 15 minutes to once a day.
  3. See

    Readings land in Mimir, up to date as of the last interval, with trends, alarm thresholds, exports and an API that can feed your BMS or energy reporting.

    One screen for every meter and gauge on the network.
10+ years on a battery
Replaceable with two screws when the interval is short or the batteries age.
LTE-M / NB-IoT cellular
Wi-Fi where a site prefers it. On cellular the sensor never touches your OT or office network.
No gateway, no hub
Each sensor talks to Mimir directly. One device per reading point, nothing in between.
Paired in under 60 seconds
iOS or Android app: scan, name the point, set the interval. The first reading follows on the next tick.

Plants and remote sites, logged without the round.

CHP plants, peak boilers, small hydro and solar parks are checked on a round because the instruments are there and the SCADA is not. Waltero reads the same meters, gauges and levels at a set interval, so the plant log keeps itself and the remote site reports without the drive.

Power & heat plantRenewable generation Generation assets

Power & heat plant

The plant round, logged without the walk.

A CHP or heat plant is full of instruments that are checked on a round: fuel tank levels, boiler and steam gauges, feedwater and dosing, a meter in a corner nobody trusts. The peak boiler plant at the edge of town sees a technician once a week. Waltero reads the same instruments at a set interval, so the plant log keeps itself and a drifting reading becomes an alarm rather than a note in the shift book.

What we monitor

  • Fuel and additive tank levels

    Vision AI reads the level gauges on oil, bio-oil and additive tanks; reorder alarms at the level you set, and a falling level with no load flags a leak.

  • Boiler, steam and feedwater gauges

    Pressure gauges on boilers, steam headers and feedwater lines read in place, with alarms when a reading leaves its normal band.

  • Temperature displays

    Flue-gas, supply and return temperatures read from the existing thermometers and panel displays at a set interval.

  • Water treatment dosing

    Drum levels for oxygen scavenger, pH and inhibitor dosing, so the treatment log is always current.

  • Feed and circulation pumps

    Run events, duration and trends from a vibration fingerprint on feedwater and network pumps, with an alert on deviation from the normal pattern.

  • Plant meters

    Make-up water, gas and the plant's own electricity from the existing meters, at the same interval as everything else.

Learn more

Talk to us about power & heat plant

What your technicians drive to today

Tick the checks staff still do by hand in this part of the network and adjust how often and how long. Every one of them is a reading a W-Sensor can take instead.

0manual readings a year
0hours of driving, walking and writing
0working days a year
Show the checklist
  • Fuel and additive tank levels Power & heat plant Daily 5 min
  • Boiler, steam and feedwater gauges Power & heat plant Weekly 10 min
  • Temperature displays Power & heat plant Daily 5 min
  • Water treatment dosing Power & heat plant Weekly 5 min
  • Plant meters Power & heat plant Monthly 15 min
  • Generation meter Renewable generation Monthly 10 min
  • Intake, forebay and trash-rack level Renewable generation Daily 5 min
  • Hydraulic and lubrication gauges Renewable generation Weekly 10 min

Estimates you can edit; minutes include getting there and writing it down. With Waltero the reading interval is a setting, and the log writes itself.

Electricity grid

Back to the network map

Meters and substations that report, without a rollout.

Customer meters are read by hand or replaced in a rollout; transformer gauges, SF6 density, panel meters and indicator lamps are read on scheduled visits and typed into a form. Waltero reads all of them in place at a set interval, with the power on and with no connection to the meter, the substation or the grid, so consumption, condition and load are a trend rather than a quarterly snapshot.

Customer & grid meters

Smart-meter data from the meters you already have, with the power on.

A smart-meter rollout means a new meter, an electrician and a power cut at every customer, and years before the last one is done. A W-Sensor goes over the existing electricity meter in minutes, with the power on, and reads the register at a set interval. It has no electrical or data connection to the meter or the grid: it reads the display from the outside, so there is nothing to cut in and nothing to attack.

What we monitor

  • No power cut to install

    The sensor mounts over the existing meter with a hinged adapter; the meter is never touched, the supply is never interrupted and no electrician is needed.

  • Air-gapped by design

    No electrical or data connection to the meter, the customer's installation or the grid. Readings go out over the cellular network, encrypted and outbound only; nothing can be reached through the sensor, and interference with it is reported as tamper.

  • Consumption at the interval you choose

    Register readings from mechanical and digital meters at customers, feeders and grid boundaries, from every 15 minutes to once a day, for billing, load profiles and losses.

  • Anomalies and outages

    A register that stops moving, a night baseline that changes or a load that vanishes becomes an alarm rather than a customer call.

  • Exact billing, no estimates

    Same-day readings across a whole customer group end estimated bills and the disputes that follow.

Learn more

Talk to us about customer & grid meters

Transmission substation

Transformer gauges read every hour, not every quarter.

The main transformers and breakers already have gauges: oil level, winding and oil temperature, tap-changer counters, SF6 density on the breakers. Most are read by a technician on a scheduled visit and typed into a form. Waltero reads them in place at a set interval, outside the protection and control system, so condition is a trend rather than a quarterly snapshot.

What we monitor

  • Transformer oil level and temperature

    Vision AI reads the oil-level sight glass and the winding and oil temperature gauges; alarm on a rising trend or a falling level.

  • SF6 density gauges

    The density gauge on every breaker read at a set interval, so a slow leak is flagged long before the low-pressure lockout.

  • Tap-changer counter

    Operation counts from the existing counter, for maintenance planned on use rather than on the calendar.

  • Station auxiliaries

    Battery charger, panel meters and auxiliary supply figures from the existing displays, read on every check.

  • Indicator lamps and flags

    A camera on the panel front flags a changed indicator or a dropped relay flag on the next check.

Learn more

Talk to us about transmission substation

Distribution substations

Thousands of substations, one sensor each.

A distribution grid has hundreds or thousands of secondary substations and almost none of them report anything. Fitting an RTU to each is a project; fitting a W-Sensor is a visit. It reads the panel meters, the transformer gauges and the substation meter at a set interval, so load, condition and losses per substation are known without a rollout across the whole grid.

What we monitor

  • Load per substation

    Current, voltage and power from the panel meters in the LV board, read in place, for capacity planning and connection decisions.

  • Transformer temperature and oil level

    The gauges on the distribution transformer read at a set interval, with alarms before a summer peak becomes a failure.

  • Substation energy meter

    Energy in against energy billed downstream, for loss calculation per substation.

  • Indicator lamps and trip flags

    A tripped breaker or a changed indicator flagged on the next check.

  • Outage and anomaly alerts

    A reading that goes to zero, or a load that is not where it was yesterday, becomes an alarm in Mimir.

Learn more

Talk to us about distribution substations

What your technicians drive to today

Tick the checks staff still do by hand in this part of the network and adjust how often and how long. Every one of them is a reading a W-Sensor can take instead.

0manual readings a year
0hours of driving, walking and writing
0working days a year
Show the checklist
  • No power cut to install Customer & grid meters — Daily — 15 min
  • Consumption at the interval you choose Customer & grid meters — Monthly — 10 min
  • Transformer oil level and temperature Transmission substation — Weekly — 10 min
  • SF6 density gauges Transmission substation — Weekly — 10 min
  • Tap-changer counter Transmission substation — Monthly — 15 min
  • Indicator lamps and flags Transmission substation — Daily — 5 min
  • Load per substation Distribution substations — Monthly — 15 min
  • Transformer temperature and oil level Distribution substations — Daily — 5 min
  • Substation energy meter Distribution substations — Monthly — 10 min
  • Indicator lamps and trip flags Distribution substations — Daily — 5 min

Estimates you can edit; minutes include getting there and writing it down. With Waltero the reading interval is a setting, and the log writes itself.

District heating & cooling

See the district heating & cooling pageBack to the network map

The heat network, from plant to customer.

Pressure and temperature in the chambers, level and temperature in the accumulator, gauges at the exchange stations and in the cooling plant: the numbers a heat network is run on are collected by visit. Waltero reads the existing instruments at a set interval, so the whole network is one trend in Mimir, alongside the customer substations.

Heat transmission & networkHeat storage & exchange stationsDistrict cooling District heating & cooling assets

Heat transmission & network

Pressure and temperature at every chamber, without driving there.

A district heating network is judged at points nobody sees: pressure at the far end, differential pressure at the critical points, temperatures in valve chambers, water in the pits. Waltero reads the existing gauges and thermometers in the chambers at a set interval and sends the readings to Mimir, so the network's condition is a trend across the map rather than a set of visits.

What we monitor

  • Pressure at critical points

    Supply and return pressure gauges at the ends of the network and at the critical points, read in place, with alarms on drift.

  • Supply and return temperature

    Thermometers in the chambers read at a set interval, so the temperature profile along the line is known.

  • Water in valve pits

    Vision AI reads the water level in chambers and pits against a calibrated scale, flagging groundwater ingress or a leak before the pit is full.

  • Network flow and heat meters

    The reading shown on flow and heat meters out in the network, read on every check.

  • Records for the network model

    Timestamped readings that calibrate the hydraulic model and support the annual loss report.

Learn more

Talk to us about heat transmission & network

What your technicians drive to today

Tick the checks staff still do by hand in this part of the network and adjust how often and how long. Every one of them is a reading a W-Sensor can take instead.

0manual readings a year
0hours of driving, walking and writing
0working days a year
Show the checklist
  • Pressure at critical pointsHeat transmission & network Weekly, 10 min
  • Supply and return temperatureHeat transmission & network Daily, 5 min
  • Water in valve pitsHeat transmission & network Daily, 5 min
  • Network flow and heat metersHeat transmission & network Weekly, 5 min
  • Accumulator level and pressureHeat storage & exchange stations Daily, 5 min
  • Tank and station temperaturesHeat storage & exchange stations Daily, 5 min
  • Primary and secondary pressureHeat storage & exchange stations Weekly, 10 min
  • Chiller and plant electricityDistrict cooling Monthly, 10 min
  • Chiller and chilled-water gaugesDistrict cooling Weekly, 10 min
  • Cold storage tank levelDistrict cooling Daily, 5 min
  • Cooling tower dosingDistrict cooling Weekly, 5 min

Estimates you can edit; minutes include getting there and writing it down. With Waltero the reading interval is a setting, and the log writes itself.

Technical specifications

Back to the network map

Built for plant rooms, not server rooms.

What the operations, OT and IT teams ask before a first installation, in one place. Everything here applies to every reading point on the network, from the accumulator tank to the secondary substation.

What it reads
Mechanical and digital meters, pressure and temperature gauges, level indicators, display panels and status lamps. Anything a person can read, the camera can.
How it reads
A photo of the instrument at each interval, read on the device by Waltero's edge AI. Only the value is transmitted, never a video stream; the image behind any reading is available for audit.
Reading interval
Configurable per sensor in Mimir, from every 15 minutes to once a day. Hourly is the usual default for plant instruments and substation gauges.
Mounting
Hinged adapter over the existing instrument. No plumbing, wiring or modification of the asset; the meter stays readable by hand.
Power
Battery powered, 10+ years at typical intervals. Batteries are replaced by removing two screws.
Environment
Sealed housing engineered for plant rooms, valve chambers, substations and outdoor cabinets.
Tamper detection
The sensor reports if it is moved or opened.
The sensor
Network
LTE-M, NB-IoT or LTE cellular with a SIM in every sensor; Wi-Fi where a site prefers it. Coverage is checked per site before installation.
OT and IT
None required on cellular. The sensor never joins your SCADA, OT or office network and needs no port, VLAN or firewall rule; it reads the instrument from the outside.
Gateways
None. Each sensor communicates with Mimir directly; there is no hub, repeater or on-site server.
Below ground and indoors
LTE-M and NB-IoT are designed for deep-indoor coverage. A connection survey per site confirms it before sensors go up.
Connectivity
Connections
Outbound only and encrypted. The sensor calls out to Mimir; nothing can call in to it.
Audit images
The image behind any reading is available on request, so a disputed value can be checked by eye.
Attack surface
No inbound ports and, on cellular, no presence on your OT or office network, so a sensor cannot be used as a way in.
Ownership
Your readings are yours: export any range as CSV, or pull them through the API.
Security & data
Readings
Every point on one screen, up to date as of the last interval, with the thumbnail behind each value.
Alarms
Thresholds and rate-of-change rules per point, with notifications to the people you choose.
Reporting
Readings per point, per site and per period; consumption per customer meter; exports to Excel for loss, tariff and ESG reporting.
Integration
REST API and webhooks; readings can be pushed to SCADA, the billing system, a historian or a data warehouse; MQTT is available.
Access
Web application on desktop and mobile; an organisation per utility, with users and roles per plant, network or team.
Mimir platform
CertifiedCEFCCPTCRBISO 9001ISO 14001

Next step

Bring your inspection round list. That is all we need.

Every energy company already has the answer written down: the list of gauges, meters, levels and panels technicians drive to and read today. One conversation about that list tells us exactly which readings we can take over for you. The checklists above are a good place to start.

Talk to an expertBack to the network map
  • A short call with your operations or maintenance manager
  • We go through the rounds list together, point by point
  • You get it back marked up: what a W-Sensor can read, how, and what it costs